The McGraw-Hill Companies
McGraw Hill Construction - Building Materials, Products and Manufacturers
home |
product centers
| find a rep |
utilities
| education | project network | SNAP Reader Service | forums
register | forgot password | remember me | help
 
MasterFormat 2004   help
 
Product Center Image
 |   |   | 


Fire Dampers

Model 75
  • UL Listed 1.5 Hour Fire Damper
  • Rollformed 22 gauge galvanized frame
  • Rollformed 22 gauge galvanized blades
  • Stainless steel closure spring (horizontal models only)
  • Available in vertical (V) or horizontal (H) models
  • Available in both single and multi-section units
  • Maximum single unit size (damper):
  • Vertical: 60”x60”
    Horizontal: 60”x60”
  • Maximum multiple unit size (damper):
  • Vertical: 120”x120”
    Horizontal: 102”x60”
  • Available in stainless steel
  • UL Listed curtain-style fire damper for static systems
  • Tested to UL 555: File R16475
  • Meets NFPA 90A requirements
  • Listed with California State Fire Marshall: Listing 3225-1577:100
  • Reference 75/105 Series sizing chart for damper sizing
  • Reference 75 Series Installation Instructions

Model 85
  • UL Listed 1.5 Hour Fire Damper
  • Rollformed 22 gauge galvanized frame
  • Rollformed 22 gauge galvanized blades
  • Stainless steel closure spring (horizontal models only)
  • Available in vertical (V) or horizontal (H) models
  • Available as single units only
  • Maximum single unit size (damper):
  • Vertical: 41”x36” or 36”x60”
    Horizontal: 60”x60”
  • Thinline frame for applications with space constraints
  • UL Listed curtain-style fire damper for static systems
  • Tested to UL 555: File R16475
  • Meets NFPA 90A requirements
  • Listed with California State Fire Marshall: Listing 3225-1577:100
  • Reference 85/95 Series sizing chart for damper sizing
  • Reference 85 Series Installation Instructions

Model 95
UL Listed 3.0 Hour Fire Damper
  • Rollformed 22 gauge galvanized frame
  • Rollformed 22 gauge galvanized blades
  • Available in vertical (V) models only
  • Available as single units only
  • Maximum single unit size (damper):

  • Vertical: 48”x49”
  • Thinline frame for applications with space constraints
  • UL Listed curtain-style fire damper for static systems
  • Tested to UL 555: File R16481
  • Meets NFPA 90A requirements
  • Listed with California State Fire Marshall: Listing 3225-1577:102
  • Reference 85/95 Series sizing chart for damper sizing
  • Reference 95 Series Installation Instructions

Model 105
UL Listed 3.0 Hour Fire Damper
  • Rollformed 22 gauge galvanized frame
  • Rollformed 22 gauge galvanized blades
  • Available in vertical (V) models only
  • Available as single units only
  • Maximum single unit size (damper):
  • Vertical: 60”x48”
  • UL Listed curtain-style fire damper for static systems
  • Tested to UL 555: File R16481
  • Meets NFPA 90A requirements
  • Listed with California State Fire Marshall: Listing 3225-1577:102
  • Reference 75/105 Series sizing chart for damper sizing
  • Reference 105 Series Installation Instructions

Model FDS S
Fire Damper Sleeve Assembly
  • UL Listed fire damper factory mounted in a galvanized sleeve
  • Available in the following lengths: 8”, 12”, 16”, 20”
  • Available in the following gauges: 14, 16, 18, 20, 22
  • Available in stainless steel (with model 75 only)
  • Damper can be ordered off-set from center for sidewall applications
  • Provides a fastening site for ductwork leading to the damper
  • Provides a platform to which retaining angle can be mounted
  • Reference Sleeve Installation Instructions

 

For installation instructions and additional information, please visit our website www.wardind.com.


Ward Industries
815 Kimberly Drive
Carol Stream, IL 60188
Tel: 800/624-8642
Fax: 866/466-9335
E-mail: info@wardind.com
Web site: http://www.wardind.com



 |   |   |