Thermafiber Safing Fire Containment Insulation
Description:THERMAFIBER Safi ng products are designed to provide life saving fi re protection in perimeter fi re containment systems, fl oor and wall penetrations, construction joints, and other fi restopping applications. These products are noncombustible, moisture-resistant, noncorrosive, nondeteriorating, mildew-proof and vermin-proof. Thermafi ber Safi ng provides thermal insulation, fi re protection, and acoustical control in many different UL and Intertek (formerly OPL) listed fi re containment assemblies of 1, 2, and 3-hr ratings. Product Options:- Safi ng 4.0 pcf, 2 or greater thickness, is available with or without a vapor retarding foil facing.
- Safi ng 6.0 pcf, 1.5 or greater thickness, is available with or without a vapor retarding foil facing.
- Recycled Content Options1:
- Special Green Fiber ............................................ 90%
- EPA Choice Fiber (US Government Buildings) ........ 75%
- Standard Fiber ...................................................... 70%
- 1Recycled content options other than standard must be specifi ed at time of order.
Installation:All fi restopping insulation should be installed per the architectural specifi cation or system specifi c test description. All compressed Safi ng insulation should be installed per the listed assembly. - Perimeter Installation: Safi ng insulation should be compression fi tted between the slab edge and the FireSpan curtain wall insulation, leaving no voids.
- Penetration Application: Safi ng insulation should be cut slightly larger than the opening and compression fi tted into the opening, leaving no voids.
- Construction Joint Application: Safi ng insulation should be compression fi tted into the joint opening, leaving no voids.
Standard Sizes: | | Thickness* | Widths** | Lengths** |
|---|
| Safi ng 4.0 pcf | 1- 6 | 16, 24, 36 | 48, 60 | | Safi ng 6.0 pcf | 1- 6 | 16, 24, 36 | 48, 60 | | Tolerances | +1/4, - 1/8 | ± 1/8 | ±1/2 | *Thicknesses are available in 1/2 increments. **Custom sizes are available upon request. | Technical Data: | | | | | | | | Tested to ASTM E 84 |
|---|
| | | Tested to ASTM C 518 | Unfaced | Foil Faced |
|---|
| Product Designation | Actual Density | k @ 75° [24°C] BTU.in/hr.sq. ft. °F | R value per inch of thickness*** | Flame Spread | Smoke Developed | Flame Spread | Smoke Developed |
|---|
| Safi ng | 4.0 pcf | 0.24 | R= 4.2 | 0 | 0 | 25 | 0 |
|---|
| Safi ng | 6.0 pcf | 0.24 | R= 4.2 | 0 | 0 | 25 | 0 |
|---|
***R = thickness divided by k | Fire-Containment Tests Per ASTM E 2307Safi ng insulation is a critical component of any perimeter fi re containment system. Thermafi ber has performed decades of testing in all of the containment systems listed below. For more complete test information, see SA707, THERMAFIBER Life-Safety Fire Containment Systems technical catalog or UL and Intertek (formerly OPL) Directories. For a full listing of containment systems visit www.thermafi ber.com and click on Fire Rated Assemblies. UL Reference = TYPE SAF - Aluminum Spandrel Curtain Wall Fire Containment
- Steel Stud-Framed/Gypsum Sheathing Curtain Wall Fire Containment
- Glass Spandrel Curtain Wall Fire Containment
- Granite Spandrel Curtain Wall Fire Containment
- Precast Concrete Spandrel
Standards Compliance:Safi ng Insulation meets the following: ASTM C 665 Non-corrosive, Type I, III ASTM C 612 Type IA, IB, II ASTM E 136 Rated Non-combustible per NFPA Standard 220 ASTM E 96 Unfaced, 50 Perms as tested ASTM E 96 Foil Faced, 0.02 Perms as tested ASTM C 1104 Absorbs less than 1% by volume ASTM E 814 or UL 1479 Safi ng Insulation used in conjunction with an approved fi ll, void, or cavity material sealant or other approved material in through penetration fi restop systems. UL 2079 Safi ng Insulation used in conjunction with an approved fi ll, void or cavity material in construction joint systems Thermafiber 3711 Mill Street Wabash , IN 46992 Tollfree: (888) 834-2371 E-mail: info@thermafiber.com Web site: http://www.thermafiber.com
|
|
|
|