SAFB (Sound Attenuation Fire Blankets)

SAFB (Sound Attenuation Fire Blankets)

Description:

THERMAFIBER Sound Attenuation Fire Blankets (SAFB) are mineral wool batts designed to stop sound, save energy, and provide life saving fi re protection. These products are noncombustible, moisture-resistant, noncorrosive, nondeteriorating, mildew-proof and verminproof. Thermafi ber SAFBs provide acoustical control, thermal insulation, and fi re protection in many different UL fi re rated wall and fl oorceiling assemblies. SAFBs resist temperatures over 2000ºF as compared to fi berglass insulation that melts around 1000ºF. SAFBs add STCs to wall and fl oor-ceiling assemblies. SAFBs can be installed in both steel stud and wood stud construction. See Thermafi ber’s SAFB Brochure (TF885) for more detail on STC and fi re ratings for multiple wall and fl oor-ceiling assemblies.

Product Options:

Recycled Content Options1:

Special “Green” Fiber ...............................................90%
EPA Choice Fiber (US Government Buildings) ...........75%
Standard Fiber .........................................................70%
1Recycled content options other than Standard must be specifi ed at time of order.

  • Standard SAFB
  • Creased SAFB – Made 1” wider than standard stud spacing to bow in the stud cavity for increased sound absorption.
Installation:
  • Interior Stud Cavity – Friction fi t SAFBs securely between studs. Butt ends of blankets closely together and fi ll all voids.
  • Creased SAFB – Bow the blankets slightly to fi t into stud cavity. Slit the blankets vertically 1” deep with a utility knife.
  • Floor-Ceiling – Friction fi t SAFBs securely between fl oor joists.
  • Ceiling Overlayment – Lay SAFBs over ceiling panels extending 48” beyond all partitions. Tightly fi t around all hangers,
  • obstructions, and penetrations.
Standard Sizes:
Thickness*Widths**Lengths**
SAFB 2.5 pcf1½”- 6”15¼”, 16”, 17”, 23”, 24”, 25”48”
SAFB 4.0 pcf**1”15¼”, 16”, 17”, 23”, 24”, 25”48”
Tolerances+1/4”, - 1/8± 1/8”±1/2”

*Thicknesses are available in 1/2” increments. **Custom sizes are available upon request.

**Non-Standard 4.0 pcf is available in thicknesses of 1 ½”-6” upon special request

***15 ¼” and 23” are recommended widths for wood stud construction


Technical Data:
Tested to ASTM E 84
Unfaced
Product DesignationNominal DensityFlame SpreadSmoke Developed
SAFB2.5 pcf00
SAFB4.0 pcf00

Acoustical Performance:

Coeffi ceints at Frequencies Per ASTM 423

Thickness125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 HzNRC
SAFB 2.5 pcf Density
2"0.340.611.071.091.071.10.95
3"0.510.991.181.030.990.961.05
4"0.831.191.271.121.121.131.20
6"1.371.321.231.161.121.121.20

***R = thickness divided by ‘k’


Standards Compliance:

SAFB Insulation meets the following:

NFPA 101 Class A rated interior fi nish
ASTM C 665 Type I, per Federal Specifi cation HH-I-521F
ASTM E 136 Rated Non-combustible per NFPA Standard 220
ASTM C 1104 Absorbs less than 1% by volume

Thermafiber
3711 Mill Street
Wabash , IN 46992
Tollfree: (888) 834-2371
E-mail: info@thermafiber.com