Technical Data:


FireSpan Curtain Wall Insulation

FireSpan Curtain Wall Insulation

Description:

THERMAFIBER FireSpan products are designed to provide life saving fi re protection in curtain wall and perimeter fi re containment systems. These products are noncombustible, moisture-resistant, noncorrosive, nondeteriorating, mildewproof and vermin-proof. FireSpan 40 & 90 provide thermal insulation, fi re protection, acoustical and vapor control in many different fi re containment assemblies of 1, 2, and 3-hr ratings.

Product Options:
  • FireSpan 40, 2” or greater thickness, is available with a vapor retarding foil facing.
  • FireSpan 90, 1” or greater thickness, is available with a vapor retarding foil facing.
  • Both FireSpan 40 and 90 are available in dark and regular colored fi bers for aesthetic purposes.
  • Recycled Content Options1:
    • Special “Green” Fiber ............................................ 90%
      Dark Fiber ............................................................. 84%
      EPA Choice Fiber (US Government Buildings) ........ 75%
      Standard Fiber ...................................................... 70%
      1Recycled content options other than standard must be specifi ed at time of order.

    Installation:

    FireSpan products should be mechanically attached to horizontal and vertical mullions with architect approved insulation fasteners. Reinforce FireSpan on the outer insulation surface at the safi ng line. Typical reinforcement members include hat channels, “L” angles, and “T” bars. Thermafi ber’s patented Impasse system is designed to quickly and easily mechanically attach FireSpan insulation to curtain wall systems.

    Standard Sizes:

    Thickness*Widths *Lengths**
    FireSpan 402”- 624”, 36”, 72”48”, 60”, 72"
    FireSpan 901”- 6”24”, 36”, 72”48”, 60”, 72"
    Tolerances+1/4”, - 1/8± 1/8”+3/4",-1/4"

    *Thicknesses are available in 1/2” increments. **Consult sales representative for custom size options.

    Tested to ASTM E 84
    Tested to ASTM C 518UnfacedFoil Faced
    Product DesignationNominal Density“k” @ 75° [24°C] BTU.in/hr.sq. ft. °F“R” value per inch of thickness***Flame SpreadSmoke DevelopedFlame SpreadSmoke Developed
    FireSpan 404.0 pcf0.24‘R’= 4.200250
    FireSpan 908.0 pcf0.24‘R’= 4.200250

    ***R = thickness divided by ‘k’

    Fire-Containment Tests Per ASTM E 2307

    FireSpan insulation is the insulation for perimeter fi re containment. Thermafi ber has performed decades of testing in all of the containment systems listed below. For more complete test information, see SA707, THERMAFIBER Life-Safety Fire Containment Systems technical catalog or UL and Intertek (formerly OPL) Directories. For a full listing of containment systems visit www.thermafi ber.com and click on Fire Rated Assemblies.

    • Aluminum Spandrel Curtain Wall Fire Containment
    • Steel Stud-Framed/Gypsum Sheathing Curtain Wall Fire Containment
    • Glass Spandrel Curtain Wall Fire Containment
    • Granite Spandrel Curtain Wall Fire Containment
    • Precast Concrete Spandre
    Standards Compliance:

    FireSpan 40 and 90 meet the following:

    ASTM C 665 Type I, III (Class A, Category 1)
    ASTM C 612 FireSpan 40 Type IA, IB, II
    ASTM C 612 FireSpan 90 Type IA, IB, II, III
    ASTM E 136 Rated Non-combustible per NFPA Standard 220
    ASTM E 96 Unfaced, 50 Perms as tested
    ASTM E 96 Foil Faced, 0.02 Perms as tested
    ASTM C 1104 Sorption less than 1% by volume
    ASTM C 356 Linear Shrinkage(2% @ 1200º F (650º C)
    ICC ES Report ER-2331

    Curtain wall products are approved by: New York City Board of Standards & Appeals – (under BSA 214-73-SM & accepted by MEA-209-82, Vol. II). Also, MEA-189-93-M and MEA-190-93-M.

    Thermafiber
    3711 Mill Street
    Wabash , IN 46992
    Tollfree: (888) 834-2371
    E-mail: info@thermafiber.com
    Web site: http://www.thermafiber.com





     |   |   |