Product Center Image
 |   |   | 



Rixson's shallow depth floor closers are recommended for low to medium traffic interior doors where traditional floor closer depth is too great for slab construction. Not recommended for high-frequency or exterior doors.

Features

  • Shallow depth case [2"(51mm)] allows installation in thin slab floor construction
  • Available offset (51), center (50), or independently hung (53)
  • Spring sizes to accommodate doors up to 4'0"(1219mm) wide
  • non hold-open models will swing to 180° (offset hung) and 135° (center hung) trim permitting
  • Hold open models available
  • Separate and independent latch and closing speed valves
  • Fully adjustable hydraulic backcheck (BC) (optional)
  • Optional delayed action ("DA") available to meet building code requirements (not available with backcheck)
  • Extended spindles available to suit most applications
  • Spindles are removable and can be changed to alter hanging application
  • Offset models available for fire door assemblies up to three hours-prefix "F"
  • "PH" model available to meet handicapped access requirements
  • Can be adjusted in cement case up to 3/16"(5mm) forward, backward and sideways with positive locking

Floor Closers for Fire Door Assemblies

Offset hung floor closers are available for fire door assemblies up to three hours ("F" Series) or 20 minutes (-20 Series), are UL listed and handed. According to NFPA 80, labeled fire doors up to 60"(1524mm) in height shall be provided with two hinges or pivots and an additional hinge or pivot for each 30"(762mm). Specify quantity of intermediate pivots required. Product features and templating are identical to regular floor closers and intermediate pivots. PH closers should not be used on fire door assembly.

Specifications

Floor closers shall be Rixson® 5000 Series. Cement case shall not exceed 2"(51mm) in depth. Closers shall be available offset, center and independently hung with separate valves for closing speed and latch. Fully adjustable hydraulic backcheck. Closer shall be adjustable within the cement case up to ± 3/16"(5mm) forward, backward and sideways with positive locking. Spindles shall be removable and interchangeable in the field.

How To Select Product

1. Offset vs. Center Hung Application


 |   |   |