When exterior wind pressures or security issues arise and a floor closer is
the best way to close a door but lighter opening forces are desired, the Rixson® 2900 Automatic Opener is the perfect solution.
Low energy operators are not designed for high traffic or heavy doors because
the mechanical closings inside are not strong enough to control the door.
By using a Rixson heavy-duty floor closer (existing or new installation) along
with a Rixson 2900 door opener, there is no need for the extra expense of a
high energy operator.
There is no special templating for either the floor closer
or the operator.
The Rixson® 2900 is a “low energy” power door operator designed
to automatically open and close doors with a lower energy opening force.
The American with Disabilities Act (ADA) is a law administered by the U.S.
Department of Justice. Its guidelines under ADA Regulation for Title III are
detailed on the ADA website: www.ada.gov.
The Rixson 2900 aids in complying with ADA and ANSI A156.19 requirements. It
functions using an A/C motor and hydraulic pump to activate a heavy-duty floor
closer controlled by an Electronic Limit Switch (ELS) circuit board. The Rixson
2900 is your best choice in a low energy power door operator with its:
- Simple instructions
- Uses push-button settings for door open and door close positions
- Push side or pull side mounting units available
- Interfaces with electric hardware and integrates with access control systems
- Critical for fire-rated doors
- Springs force provides the feel of a normal manual door closer
- Door can be opened manually if desired
- Wall switches
- Motion sensor
- Radio frequency device
- Push and Go
- 0-30 seconds (5 seconds minimum required for ADA and ANSI A156.19)
- Choice of indefinite hold open features
- Door closes if it hits an obstruction while opening
- Door re-opens once if it hits an obstruction while closing
- Push Side or Pull Side Applications
- Power Assist selector switch
- Push and Go selector switch
- Open/Close Obstruction Detection
- Motor startup delay adjustment
- Vestibule Function Delay adjustment (For sequencing two or more units)
- Door Hold Open Delay adjustment
- Single Pole Double Throw (SPDT) Relay Output
- SPDT Relay Output time adjustment
- SPDT Alarm Output
- Blow Open Function for Smoke Ventilation
- Infinite Hold Open function
- Presence Detector Input
- 24 VDC @ 500 mA output
- Selector Mode Switch (3 position)
- OFF -Turns unit off
- ON -Turns unit on
- HOLD OPEN - Activates the unit to the hold open position indefinitely
- Power Input 120 VAC, 60 Hz (+10%, -15%)
- Current Draw 2 amp
- Auxiliary Output 24 VDC @ 500 mA
- SPDT relay output for controlling electric strikes or electric locks not to exceed 1 amp @ 30 VDC
- Americans with Disabilities Act (ADA)
- BHMA 156.19 for Low Energy and Power Assist operated doors
- Spring-buffered stop assembly in slide track
- 1/8"(3mm) maximum frame reveal
- From 1/8" to 3"(3 to 76mm) frame reveal
- Specify hand when ordering
- Maximum frame reveals as charted
- Spring-buffered stop in arm shoe assembly
| SERIES |
REVEAL RANGE |
| 2910 |
-1/4" to 4-3/4* (57 to 121mm)* |
| 2915 |
-13/16" to 7-3/8 (122 to 187mm) |
| * Reveals less than 2-1/4"(57mm) may be
achieved by field cutting the adjusting rod |
Note: Door opening degree determined by floor closer.
- Maximum frame reveals as charted
- Spring-buffered stop assembly in arm shoe
| SERIES |
REVEAL RANGE |
| 2910-D |
-1/4" to 4-3/4* (57 to 121mm)* |
| 2915-D |
-13/16" to 7-3/8 (122 to 187mm) |
| * Reveals less than 2-1/4"(57mm) may be achieved by
field cutting the adjusting rod |
Note: Contact factory for use on doors
exceeding 250 lbs.
Heavyweight high-traffic doors that require automatic opening shall use the
low energy operator in conjunction with a heavy-duty floor closer. Operator
shall be for opening of door only.
Door shall be installed in the floor and shall have separate and independent
closing speeds with back check turned to lightest setting.
Door controls (interior/exterior) for swinging doors shall be low energy
operators. Door closing force shall be adjustable to ensure adequate closing
control. Door operator shall have an adjustable backcheck feature to cushion
the door opening speed if opened violently. Low energy operation to cycle the
door open as controlled by the body/pump and motor assembly adjustments. Power
operator unit shall provide conventional door closer opening and closing forces
unless the power operator motor is activated by an initiating device. Motor
assist shall be adjustable from 0 to 30 seconds in 5 second increments. Motor
assist shall restart the time cycle with each activation of the initiating
device. Unit shall have a three-position selector mode switch that shall permit
unit to be switched “ON” to monitor for function activation, switched
to “H/O” for indefinite hold open function or switched to “OFF,” which
shall deactivate all control functions but will allow standard door operation
by means of the internal mechanical closer. Door control shall be adjustable
to provide compliance with the requirements of the Americans with Disabilities
Act (ADA) and ANSI standards A117.1 and A156.19.
All operators shall meet UL, cUL, UL10c and UL10B standards. All operators
are to be fire rated. All operators to have push and go function to activate
power operator or power assist function. All operators to have push button
controls for setting door close and door open positions. All operators to have
open obstruction detection and close obstruction detection built into the unit.
All operators to have door closer assembly with adjustable spring size, backcheck
valve, sweep valve, latch valve, speed control valve and pressure adjustment
valve to control door closing. All operators to have motor start-up delay,
vestibule interface delay, electric lock delay and door hold open delay up
to 30 seconds. All operators shall close door under full spring power when
power is removed. All operators to have inputs for smoke ventilation doors,
which allow doors to power open upon fire alarm activation and hold open indefinitely
or until fire alarm is reset. All operators to have a presence detector input
to prevent a closed door from opening or a door that is fully opened from closing.
All operators to have a hold open toggle input to allow remote activation for
indefinite hold open; door closes the second time the input is activated. All
operators to have vestibule inputs to allow sequencing operation of two units.
All operators to have a 24 VDC @ 500 mA output for controlling electric strikes,
electromagnetic locks or radio frequency receivers. All operators to have an
SPDT relay for interfacing with latch retraction exit devices, electric strikes,
etc. All operators to be hard wired with power input of 120 VAC@60HZ
Note: For further detailed specification data,
consult our website, www.rixson.com.
|