Flushlok II, a front-set, thermally broken, single-span slim line storefront
system, is specifically designed for installation with insulated glass, but
may be adapted for installation with other infills. Its very efficient thermal
qualities are achieved through the use of a Celcon clip that separates the face
cap from the back member.
Flushlok II is available in two standard face cap depths and three back member
depths for structural integrity (dependent upon windload conditions) to result
in overall system depths of from 4 1/2" to 6" in 1/2" increments.
All framing members are square cut, which, when combined with screw spline construction,
allows for ease of fabrication and installation in either unitized or modular
mode. Also, shear block construction can be specified in order to obtain greater
flexibility. The Celcon clip thermal separation between the face cap and back
member allows for the use of different colors for the face and back members, thus
adding to the versatility of this economical, thermal, storefront system.
| Description |
Test
Method |
Allowable |
Achieved |
| Air |
ASTM
E-283 |
.06 cfm/sqft @ 6.24 psf |
.04 cfm @ 6.24 psf |
Water
(Static) |
ASTM
E-331 |
No Uncontrolled
Water @ 10.0 psf |
Passed |
Water
(Dynamic) |
ASTM
E-501.1 |
No Uncontrolled
Water @ 10.0 psf |
Passed |
| Structural |
ASTM
E-330 |
No Permanent
Deformation @ 30 psf |
Passed |
| CRF |
AAMA 1503.1 |
N/A |
57.0 |
| U Value |
AAMA 1503.1 |
N/A |
.59 BTU/hr/ft2/ºF |
|