TITE-LOC Panels combine structural panel performance with architectural panel aesthetics. TITE-LOC Panels are corrective leveled to provide superior panel flatness. A factory-applied sealant bead is applied for additional weather resistance. (minimum panel length is 4 feet)
TITE-LOC Panels feature a 2" leg height that requires mechanical field seaming after installation. Panels include a concealed-fastener floating clip system designed to allow for thermal expansion/contraction. For further details, please contact PAC.
TITE-LOC Panels are factory-formed to length and field seamed to a 90º lock. Tite-Loc panels have been designed for application on roof slopes as low as 1/2:12 pitch. As an additional labor-saver, the Tite-Loc seamer has been designed to travel both up and down slope during installation. Tite-Loc panels are available in 12, 16 and 18" widths. Materials available include 22 and 24 gage steel; .032 and .040 aluminum.
TITE-LOC Panels are produced in a labor-saving one-piece design.
TITE-LOC Panels are available with striations.
TITE-LOC Panels are available with factory cut eave notching.
Tite-Loc Plus Panels are factory-formed to length and designed to be field-seamed to 180º. The panel combines an attractive thin-rib profile with superior structural performance.
Tite-Loc Plus panels are designed for application over a wide variety of substrates in slopes as low as 1/2: 12 pitch. Tite-Loc Plus panels are available in 12", 16" and 18" widths.
Materials available include 22 and 24 ga. steel; .032 aluminum.
TITE-LOC Panels are intended for use in architectural and structural roofing. Substrates may include 5/8” (min.) plywood, nailboard insulation or equal with an underlayment of 30# (min.) roofing felt applied horizontally from eave to ridge. Other substrates may include metal decking, purlins or rigid insulation in conjunction with bearing plates.
A minimum 1/2:12 roof pitch is required. Contact Petersen for further detail assistance on projects. Consult a local architect/engineer for compliance with local codes and conditions.
TITE-LOC Panels carry a UL 90 classification over a wide variety of substrates and assemblies including 5/8” plywood, purlins, and rigid insulation in conjunction with bearing plates (ULConstruction No. 90, 176, 180, 238B, 437, 449, 451, 452, 487). For further details, contact Petersen Aluminum Corp.
- UL-580 Class 90 wind uplift
- UL-790 Class A fire rated
- UL-263 fire resistance rated
- UL-2218 impact resistance rated
- UL-90 rated aluminum panel up to 16” O.C.
- FM-I90 Rated (Tite-loc Plus Only)
TITE-LOC Panels meet the full performance requirements of the ASTM E283/1680 air infiltration test and the ASTM E331/1646 water penetration test. TITE-LOC Panels have been tested for structural performance under uniform static air pressure differences per ASTM E1592. Please contact Petersen Aluminum Corporation for complete test results.
- 24 ga. G-90 hot-dipped galvanized steel
- 22 ga. G-90 hot-dipped galvanized steel
- .032 3105-H14 aluminum
- .040 3105-H14 aluminum (Tite-Loc Panel only)
- 24 Gauge Steel: 42 Standard Colors
- 22 Gauge Steel: 11 Standard Colors
- Aluminum: 37 Standard Colors
- Smooth and stucco embossed textures
- 20-year non-prorated finish warranty
- Galvalume Plus available on indicate panel materials
All flashing and trim will be fabricated by manufacturer or qualified fabricator. Flashing shall be PAC-CLAD aluminum (.032-.063 gauge as specified) or PAC-CLAD steel (24 ga. or 22 ga. as specified). A 20 year, non-prorated finish warranty shall be supplied covering finish performance.
Petersen Aluminum Corporation
1005 Tonne Road
Elk Grove Village, IL 60007
Toll-Free: 800-PAC-CLAD
Fax: 800-722-7150 or 847-956-7968
Web site: http://www.pac-clad.com
|