Penco Products, Inc.
Subsidiary of Vesper Corporation
P.O. Box 158
Skippack, PA 19474
Phone: (610) 666-0500
Fax: (610) 666-7561
E-mail: general@pencoproducts.com
Website: http://www.pencoproducts.com
Steel Lockers - 10500
Vanguard Locker Overview
These lockers have been the industry standard for rugged, dependable
design. They come in a wide variety of configurations and sizes. Large
doors feature the exclusive patented Vanguard die cast handle. Special
nylon glides fastened to the latch channel assembly help to minimize noise.
Recessed handles are available as an option. Smaller doors feature friction-catch
door pulls. Doors have louvers. All types accept built-in locks and padlocks.
VANGUARD STANDARD LOCKER SPECIFICATIONS
MATERIALS
SHEET STEEL: All parts made from prime grade mild cold rolled
sheet steel free from surface imperfection, and capable of taking a high
grade enamel finish.
HINGES: .074" thick, 2" high, double spun, full loop, tight pin,
five-knuckle hinges, projection welded to door frame and securely fastened
to the door with 2 steel rivets. Doors over 42" high shall have three hinges,
all other doors shall have two hinges.
FINISHING: Chemically pretreat metal with a six stage cleaning
phosphatizing and metal preparation process. Finish coat shall be hot airless
electrostatically applied enamel baked on at 350 to 400 degrees. Select
colors from manufacturer's minimum standard 20 colors. All lockers shall
be painted inside and outside with the same color.
EQUIPMENT: Coat hooks and coat rods are zinc plated. Truss fin
head bolts and hex nuts are zinc plated.
FABRICATION GENERAL
CONSTRUCTION: Built on the unit principle - each locker shall
have an individual door and frame, individual top, bottom, back and shelves
with common intermediate uprights separating compartments. Lockers shall
be fabricated square, rigid and without warp. Doors shall be flat and free
of distortion.
DOOR FRAME: All door frame members to be not less than 16 gauge
formed to a channel shape. Vertical members to have an additional flange
to provide a continuous door strike. Intermembering parts to be mortised
and tenoned and electrically welded together in a rigid assembly capable
of resisting strains.
Cross frame members of 16 gauge channel shapes including intermediate
cross frame on double and triple tier lockers shall be securely welded
to vertical framing members to ensure rigidity.
BODY: Bolt spacing in locker body construction not to exceed
9" o.c. All locker body components shall be made of cold rolled steel specially
formed for added strength and rigidity and to ensure tight joints at fastening
points. Tops & bottoms shall be 24 gauge with three sides formed 90
degrees and the front offset formed to be flush with the horizontal frame
member. Shelves shall be 24 gauge with four sides formed to 90 degrees,
the front edge shall have a second bend. Backs & sides shall be 24
gauge.
DOORS: Doors 30" or higher shall be formed from one piece 16
gauge cold rolled sheet steel. Doors less than 12" wide shall be 18 gauge.
Formations shall consist of a full channel shape on the lock side of adequate
depth to fully conceal the lock bar, channel formation on the hinge side,
and right angle formations across the top and bottom. Doors over 15" wide
x 60" or 72" high shall have a 3" wide 20 gauge full height reinforcing
pan welded to the inside face of the door on 6" centers.
Doors for box lockers 3, 4, 5, and 6 tier high shall have channel formations
on lock and hinge side and have right angle flanges on the top and bottom.
Doors less than 15" wide shall be 18 gauge, 15" wide or wider shall be
16 gauge. Box locker door for 3, 4, 5, and 6 openings high shall be pre-punched
for padlock latch and friction catch and built-in combination and key locks.
DOOR HANDLE 1 & 2 TIER, 2 PERSON & DUPLEX: Handle to
consist of zinc alloy die-cast case and handle. 40,000 PSI maximum tensile
strength, chrome plated. Handle to be pulled out to move up latch bar and
open door in one motion. Padlock eye for use with 9/32" diameter padlock
shackle to be an integral part of handle and to be so located that extension
of handle forms a padlock strike. Attachment to latch bar shall be tamper-proof
and concealed inside the door. The case shall be kick-proof type, shielding
the movable part and provide a padlock strike to prevent scratching and
marring the door. A lock hole cover plate shall be provided for use with
padlocks.
DOOR LATCHING 1 & 2 TIER, 2 PERSON & DUPLEX: Doors to
have latch clip engaging the door frame at three points on doors over 42"
high and two points on all other doors. Locking device to be positive,
automatic type, whereby locker door may be locked when open, then closed
without unlocking. One rubber silencer shall be firmly secured in the frame
at each heavy gauge latch hook. Latch clips shall be glass filled nylon
for long life and low friction and shall hold doors shut by engaging the
latch hooks. The latch channel assembly shall be quieted by the use of
unique nylon glides to reduce noise.
DOOR HANDLE & LATCHING 3 TO 6 TIER BOX LOCKERS: Doors shall
be punched for use with padlocks or built-in locks. Doors for use with
padlocks shall be equipped with an 18 gauge combination door pull, staple
and lock hole cover plate with integral friction catch.
VENTILATION: Louvers shall be provided in groups of 6 at the
top & bottom of doors 60" or higher, 3 and 6 louvers for 36" high,
and a minimum of one group of 6 louvers for 30" high doors. Doors 24" high
or less shall have a minimum of one group of 3 louvers.
NUMBER PLATES: Each locker to be supplied with a polished aluminum
number plate, 2-1/4" wide x 1" high, with black numerals not less than
3/8" high. Number plates shall be attached to the face of the door with
two aluminum rivets.
INTERIOR EQUIPMENT: Single-tier lockers 60" or higher shall have
a hat shelf located approximately 9" below the top of locker; if less than
18" deep, locker shall have three single-prong hooks and one double-prong
ceiling hook. Single tier lockers 18" or more in depth shall have a coat
rod instead of a ceiling hook. 30" & 36" high lockers shall have three
single-prong wall hooks and one double-prong ceiling hook. Hooks to be
attached with two bolts per hook. 20" & 24" high lockers to have three
wall hooks for 12" wide, and four wall hooks for 15" wide and wider.
LOCKER ACCESSORIES
See locker Accessory Specifications.
OPTIONS
BODY: Locker shall be assembled using rivets.
RECESSED HANDLE; 1, 2 & 3 TIER: Delete the standard handle
and provide handles recessed in the door with finger lift control. 20 gauge
drawn pocket shall be brushed stainless steel securely fastened to the
door with two tabs plus a positive tamper resistant decorative fastener.
The pocket shall be of sufficient depth to prevent a combination padlock,
built-in combination lock or key lock from protruding beyond the face of
the door. A lock hole cover plate shall be provided for use with padlocks.
The lifting piece shall be 14 gauge formed steel, attached to the latching
channel with one concealed retaining lug and one rivet assuring a positive
two point connection. Handle finger lift shall have a padlock eye for use
with a 9/32" diameter padlock shackle. It shall have a sound deadening
molded comfortable finger lift attached with a rivet. The bottom of the
pocket shall have holes for attaching the number plate with two aluminum
rivets, and shall be angled to facilitate visibility of the number plate.
SOUND-DAMPENING PANELS (MEDALLION OPTION): Panels are designed
to reduce sound levels when doors are slammed. They are 22 gauge and are
die formed and have a full perimeter flange spot welded flush to the inside
door surface and contain sound-dampening material. Louvers are not used
when sound-dampening panels are provided.
SIDE AND BACK VENTILATION: Sides and/or backs shall be perforated
with 1/2" diameter holes in patterns of 42 holes per group.
DOOR VENTILATION: Visual perforations shall consist of 5/8" wide
x 1-1/8" high rectangular perforations in the door in standard manufacturer's
patterns. Doors with visual perforations shall not have louvers.
Mini louvers shall be 5/8" wide x 1/4" high and be placed in doors in
manufacturer's standard pattern. Doors with mini louvers shall not have
standard louvers.
A.D.A. COMPLIANT LOCKERS: Handicap lockers shall have recessed
handles and shall be single tier or the lower opening of a double tier
locker. Locker bottom shall be a minimum of 9" off the floor, or an extra
shelf placed 9" off the floor. Single tier lockers shall have a shelf 48"
off the floor. Doors assigned for handicapped use shall have an appropriate
symbol sign.
EXECUTION
INSTALLATION: Install metal lockers at location shown in accordance
with manufacturer's instructions for plumb, level, and flush installation.
ANCHOR LOCKERS to the floor and wall 48" on center or less as
recommended by the manufacturer.
INSTALL SLOPING HOODS AND METAL FILLERS using concealed fasteners.
Provide flush hairline joints against adjacent surfaces.
INSTALL BENCHES by fastening bench tops to pedestals and securely
anchoring to the floor using appropriate anchors for the floor material.
ADJUST & CLEAN: Adjust doors and latches to operate without
binding. Verify that latches are operating satisfactorily.
TOUCH UP marred finishes with factory supplied paint.
ACCEPTABLE MANUFACTURERS:
1. Penco Products, Inc., Oaks, PA - Vanguard Lockers
PENCO RESERVES THE RIGHT TO VARY SPECIFICATIONS CONSISTENT WITH ITS
POLICY OF CONTINUOUS PRODUCT IMPROVEMENT.
|