Steel Lockers 10500
Invincible II Heavy Duty Team Room Locker Overview
Invincible II lockers are designed for heavy duty use in the storage
of athletic gear, or wherever a high degree of ventilation is required.
The doors and sides are perforated with a diamond-shaped pattern for the
free flow of air. For extra durability, the doors are made from 14
gauge steel, and the sides, tops, bottoms and shelves are 16 gauge steel.
Backs are 18 gauge. Stainless steel recessed handles are standard
on 1, 2 and 3 tier models.
INVINCIBLE II HEAVY DUTY VENTILATED LOCKER SPECIFICATIONS
MATERIALS
SHEET STEEL: All parts made from prime grade mild cold
rolled sheet steel free from surface imperfection, and capable of taking
a high grade enamel finish.
HINGES: .074" thick, 2" high, double spun, full loop, tight
pin, five-knuckle hinges, projection welded to door frame and securely
fastened to the door with 2 steel rivets. Doors over 42" high shall
have three hinges, all other doors shall have two hinges except the 24"
wide x 60"or 72" doors which shall have four hinges.
FINISHING: Chemically pretreat metal with a six stage cleaning
phosphatizing and metal preparation process. Finish coat shall be
hot airless electrostatically applied enamel baked on at 350 to 400 degrees.
Select colors from manufacturers minimum standard 20 colors. All
lockers shall be painted inside and outside with the same color.
EQUIPMENT: Coat hooks and coat rods are zinc plated. Truss
fin head bolts and hex nuts are zinc plated.
FABRICATION GENERAL
CONSTRUCTION: Built on the unit principle - each locker
shall have an individual door and frame, individual top, bottom, back and
shelves with common intermediate uprights separating compartments.
Lockers shall be fabricated square, rigid and without warp. Doors
shall be flat and free of distortion.
DOOR FRAME: All door frame members to be not less than
16 gauge formed to a channel shape. Vertical members to have an additional
flange to provide a continuous door strike. Intermembering parts
to be mortised and tenoned and electrically welded together in a rigid
assembly capable of resisting strains.
Cross frame members of 16 gauge channel shapes including intermediate
cross frame on double and triple tier lockers shall be securely welded
to vertical framing members to ensure rigidity.
BODY: Bolt spacing in locker body construction not to exceed
9" o.c. All locker body components shall be made of cold rolled steel
specially formed for added strength and rigidity and to ensure tight joints
at fastening points. Tops & bottoms shall have three sides formed
90 degrees and the front offset formed to be flush with the horizontal
frame member. Shelves shall have sides formed to 90 degrees, the
front edge shall have a second bend. Backs shall be 18 gauge; all
other body parts shall be 16 gauge.
DOORS: Doors 20" or higher shall be formed from one piece
14 gauge cold rolled sheet steel. Formations shall consist of a full
channel shape on the lock side of adequate depth to fully conceal the lock
bar, channel formation on the hinge side, and right angle formations across
the top and bottom. Doors over 15" wide and over 30" high shall have
a 3" wide 20 gauge full height reinforcing pan welded to the inside face
of the door on 6" centers.
Doors for box lockers 4, 5, 6, 8 & 9 tiers high shall be 14 gauge
steel and have channel formations on lock side and hinge side and have
right angle flanges on the top and bottom.
DOOR HANDLE & LATCHING 1, 2 & 3 TIER: Handles shall
be recessed in the door and be finger lift control. The 20 gauge
drawn pocket shall be brushed stainless steel securely fastened to the
door with two tabs plus a positive tamper resistant decorative fastener.
The pocket shall be of sufficient depth to prevent a combination padlock,
built-in combination lock or key lock from protruding beyond the face of
the door. A lock hole cover plate shall be provided for use with
padlocks.
The lifting piece shall be 14 gauge formed steel, attached to the latching
channel with one concealed retaining lug and one rivet assuring a positive
two point connection. Handle finger lift shall have a padlock eye
for use with a 9/32" diameter padlock shackle. It shall have a sound
deadening molded comfortable finger lift attached with a rivet.
Doors to have latch clip engaging the door frame at three points on
60" & 72" high and two points on 20" through 36" high doors.
Locking device to be positive, automatic type, whereby locker door may
be locked when open, then closed without unlocking. One rubber silencer
shall be firmly secured in the frame at each heavy gauge latch hook.
Latch clips shall be glass filled nylon for long life and low friction
and shall hold doors shut by engaging the latch hooks. Latch hooks
on diamond-perforated lockers shall have tamper guards. The latch
channel assembly shall be quieted by the use of unique nylon glides.
DOOR HANDLE & LATCHING 4 TO 9 TIER BOX LOCKERS: Doors
shall be punched for use with padlocks or built-in locks. Doors for
use with padlocks shall be equipped with an 18 gauge combination door pull,
staple and lock hole cover plate with integral friction catch.
VENTILATION: All locker sides and doors 20" or higher shall
be perforated with diamond-shaped openings 3/4" wide x 1-1/2" high in a
quantity and pattern to insure maximum ventilation and maintain structural
strength. All other doors shall have small diamond-shaped perforations
7/16" wide x 15/16" high.
NUMBER PLATES: Each locker door to be supplied with a polished
aluminum number plate, 2-1/4" wide x 1" high, with black numerals not less
than 3/8" high. Number plates shall be attached to the face of the door
with two aluminum rivets.
INTERIOR EQUIPMENT: Locker openings 60" or higher shall have
a hat shelf located approximately 9" below the top of locker. Locker
openings 30" or higher, 12" or 15" wide and less than 18" deep shall have
three single-prong hooks and one double-prong ceiling hook. Lockers
18" or more in depth shall have a coat rod instead of a ceiling hook.
20" & 24" lockers shall have three wall hooks only. Hooks to
be steel, ball tip zinc plated, attached with two bolts per hook.
LOCKER ACCESSORIES: Lockers shall be furnished with the
accessories selected from the Accessory Specifications.
OPTIONS
BODY: Lockers shall be assembled using rivets.
DOORS: Box locker doors 4 to 9 tier, as an alternative
option each door shall be furnished with a stainless steel padlock strike.
DOOR HANDLE & LATCHING 4 TO 9 TIER BOX LOCKERS: As
an alternate option, each door shall be provided with a finger operated
11 gauge slam latch with an electrogalvanized trigger, and a spring contained
in a 14 gauge case welded to the door. The spring latch engages a
13 gauge hasp welded to the frame. Rubber bumpers shall be securely
installed in the frame.
DOOR VENTILATION: Delete diamond perforations in the doors
and substitute with standard louvers, or mini louvers may be substituted
and shall be 5/8" wide x 1/4" high. Louvers shall be placed in doors
in manufacturer's standard pattern.
A. D. A. COMPLIANT LOCKERS: Handicap lockers shall have
recessed handles and shall be single tier or the lower opening of a double
tier locker. Locker bottom shall be a minimum of 9" off the floor,
or an extra shelf placed 9" off the floor. Single tier lockers shall
have a shelf 48" off the floor. Doors assigned for handicapped use
shall have an appropriate symbol sign.
EXECUTION
INSTALLATION: Install metal lockers at location shown in
accordance with manufacturers instructions for plumb, level, and flush
installation.
ANCHOR LOCKERS to the floor and wall 48" on center or less as
recommended by the manufacturer.
INSTALL SLOPING HOODS AND METAL FILLERS using concealed fasteners.
Provide flush hairline joints against adjacent surfaces.
INSTALL BENCHES by fastening bench tops to pedestals and securely
anchoring to the floor using appropriate anchors for the floor material.
ADJUST & CLEAN: Adjust doors and latches to operate
without binding. Verify that latches are operating satisfactorily.
TOUCH UP marred finishes with factory supplied paint.
ACCEPTABLE MANUFACTURERS
1. Penco Products, Inc., Oaks, PA - Invincible II Lockers
PENCO RESERVES THE RIGHT TO VARY SPECIFICATIONS CONSISTENT WITH ITS
POLICY OF CONTINUOUS PRODUCT IMPROVEMENT.
|