Lockers 10500
Invincible II Defiant Single Point Latch (SPL) Locker Overview
Available in 1, 2 and 3 tier models. Same as the Invincible II Lockers
except that these lockers have a 14 gauge one piece door with integral
box beam stiffening reinforcements on the hinge and latch sides plus a
full length continuous hinge. For ease of maintenance, there are
no moving latch parts. Stainless steel recessed pocket has integral
finger grip door pull. Accepts built-in locks or padlocks.
INVINCIBLE II HEAVY DUTY VENTILATED LOCKER WITH DEFIANT SINGLE POINT
LATCH (SPL) SPECIFICATIONS
MATERIALS
SHEET STEEL: All parts made from prime grade mild cold
rolled sheet steel free from surface imperfection, and capable of taking
a high grade enamel finish.
HINGES: 16 gauge continuous type hinge riveted to the frame and
the door for the full height of the door.
FINISHING: Chemically pretreat metal with a six stage cleaning
phosphatizing and metal preparation process. Finish coat shall be
hot airless electrostatically applied enamel baked on at 350 to 400 degrees.
Select colors from manufacturers minimum standard 20 colors. All
lockers shall be painted inside and outside with the same color.
EQUIPMENT: Coat hooks and coat rods are zinc plated. Truss
fin head bolts and hex nuts are zinc plated.
FABRICATION GENERAL
CONSTRUCTION: Built on the unit principleeach locker shall
have an individual door and frame, individual top, bottom, back and shelves
with common intermediate uprights separating compartments. Lockers
shall be fabricated square, rigid and without warp. Doors shall be
flat and free of distortion.
DOOR FRAME: All door frame members to be not less than
16 gauge formed to a channel shape. Vertical members to have an additional
flange to provide a continuous door strike. Intermembering parts
to be mortised and tenoned and electrically welded together in a rigid
assembly capable of resisting strains.
Cross frame members of 16 gauge channel shapes including intermediate
cross frame on double and triple tier lockers shall be securely welded
to vertical framing members to ensure rigidity.
BODY: Bolt spacing in locker body construction not to exceed
9" o.c. All locker body components shall be made of cold rolled steel
specially formed for added strength and rigidity and to ensure tight joints
at fastening points. Tops & bottoms shall have three sides formed
90 degrees and the front offset formed to be flush with the horizontal
frame member. Shelves shall have sides formed to 90 degrees, the
front edge shall have a second bend. Backs shall be 18 gauge; all
other body parts shall be 16 gauge.
DOORS: Doors shall be formed from one piece 14 gauge steel.
Formations shall be box formed stiffeners on the hinge side and latch sides.
Both formations shall have a 1/2" flange spot welded to the inside face
of the door on 4-1/2" centers. Top and bottom flanges shall have
one 90 degree bend. For long life, the door shall be manufactured
from one integral piece. Door shall be manufactured to allow maximum
ventilation and stiffness utilizing two box formed stiffeners.
DOOR HANDLE & LATCHING 1, 2 & 3 TIER: Handles shall
be recessed in the door. The formed pocket shall be brushed stainless
steel securely fastened to the door with two lugs plus a positive tamper
resistant fastener. The pocket shall be of sufficient depth to prevent
a combination padlock, built-in combination lock or key lock from protruding
beyond the face of the door. A lock hole cover plate shall be provided
for use with padlocks. All pockets shall be 20 gauge drawn steel
for superior strength. Door pull shall be formed in the pocket.
Pocket and pull shall be integral.
Doors shall have a catch to retain unlocked doors in the closed position.
Locking shall be accomplished by an 11 gauge lug welded to the locker frame.
The lug shall include a surface for the bolt of a built-in combination
or key lock to engage and a padlock staple that protrudes through the 20
gauge pocket. The lug shall include an anti pry flange and notch
to deter prying open when locked. Rubber door silencers shall be
firmly attached to the locker frame.
VENTILATION: All locker sides and doors 20" or higher shall
be perforated with diamond-shaped openings 3/4" wide x 1-1/2" high in a
quantity and pattern to ensure maximum ventilation and maintain structural
strength. All other doors shall have small diamond-shaped perforations
7/16" wide x 15/16" high.
NUMBER PLATES: Each locker door to be supplied with a polished
aluminum number plate, 2-1/4" wide x 1" high, with black numerals not less
than 3/8" high. Number plates shall be attached to the face of the door
with two aluminum rivets.
INTERIOR EQUIPMENT: Locker openings 60" or higher shall have
a hat shelf located approximately 9" below the top of locker. Locker
openings 30" or higher, 12" or 15" wide and less than 18" deep shall have
three single-prong hooks and one double-prong ceiling hook. Lockers
18" or more in depth shall have a coat rod instead of a ceiling hook.
20" & 24" lockers shall have three wall hooks only. Hooks to
be steel, ball tip zinc plated, attached with two bolts per hook.
LOCKER ACCESSORIES: Lockers shall be furnished with the
accessories selected from the Accessory Specifications.
OPTIONS
BODY: Lockers shall be assembled using rivets.
DOOR VENTILATION: Delete diamond perforations in the doors
and substitute with standard louvers, or mini louvers may be substituted
and shall be 5/8" wide x 1/4" high. Louvers shall be placed in doors
in manufacturer's standard pattern.
EXECUTION:
INSTALLATION: Install metal lockers at location shown in
accordance with manufacturers instructions for plumb, level, and flush
installation.
ANCHOR LOCKERS to the floor and wall 48" on center or less as
recommended by the manufacturer.
INSTALL SLOPING HOODS AND METAL FILLERS using concealed fasteners.
Provide flush hairline joints against adjacent surfaces.
INSTALL BENCHES by fastening bench tops to pedestals and securely
anchoring to the floor using appropriate anchors for the floor material.
ADJUST & CLEAN: Adjust doors and latches to operate
without binding. Verify that latches are operating satisfactorily.
TOUCH UP marred finishes with factory supplied paint.
ACCEPTABLE MANUFACTURERS
1. Penco Products, Inc., Oaks, PAInvincible II Defiant SPL Lockers
PENCO RESERVES THE RIGHT TO VARY SPECIFICATIONS CONSISTENT WITH ITS
POLICY OF CONTINUOUS PRODUCT IMPROVEMENT.
|