THERMA-FLOOR®
Underlayment
03 54 00/MAX BuyLine 5015

Maxxon® Corporation
920 Hamel Road, PO Box 253
Hamel, MN 55340
Phone: 1-(800) 356-7887 or (763) 478-9600
Fax: (763) 478-2431
E-mail: info@maxxon.com
Web site: www.maxxon.com

Therma-Floor is a gypsum underlayment designed to pour over hot water tubes or electric heating cables. It acts as the thermal mass for any radiant floor system. Therma-Floor encases the tubes or cables in crack resistant, non-combustible gypsum. Its special formula resists breakdown to 150 °F (66 °C). And because it’s poured only 1 ¼ " (32 mm) thick, the heating system is more responsive and more comfortable.

NOW ALWAYS MADE IN A GREEN FORMULATION.

THERMA-FLOOR® TECHNICAL DATA

Compressive Strength:

Typical range of 2,000 to 3,000 psi (14 to 21 MPa)

VOC Content:

<24 mg/m3

Specific Heat:

.224 Btu/(lb · °F) at 85°F (.9385 kJ[kg · °C] at 29.44°C)

Weight:

At 1-1/4", less than 12 lbs./sq.ft. (At 32 mm, less than 58.7 kg/m2;)

Dry Density:

115 lbs./ft.3; (1840 kg/m3;)

Point Loading:

Typical loading of up to 2,500 lbs. on a 1" (1,135 kg on a 25.4 mm) diameter disc

Acoustical Performance:

The acoustical performance of Therma-Floor is similar to Gyp-Crete Floor Underlayment. Contact Maxxon Corporation for reports.

Coefficient of Conductivity (K):

4.96 Btu/(h­ · ft2 · °F) (.7142 W/[m · °C])

Thermal Resistance at 1" Thickness

R-0.208

Surface Burning Characteristics:

Flame spread: 0
Fuel contributed: 0
Smoke density: 0

GREENGUARD Indoor Air Quality Certified ®

THERMA-FLOOR® UNDERLAYMENT CSI FORMATTED SPECIFICATIONS FOR THE FOLLOWING APPLICATIONS APPEAR IN THIS PROFILE. Customized CSI formatted specifications are available upon request, or on our website at www.maxxon.com.

• As the Heat Mass for Radiant Floor Heating
 

Sample USGBC LEED Credit Areas*

Project

Credit

Category

How Requirement is Fulfilled

Indoor Environmental Quality

EQ 3.2

Construction Indoor Air Quality Management Plan

GREENGUARD Certified (Field testing MUST be completed prior to claiming credit)

Materials & Resources

MR 4.1 – 4.2

Recycled Content

Fly Ash

MR 5.1 – 5.2

Local/Reg. Materials

Manufactured in Blue Rapids, KS 66411; Las Vegas, NV 89035; Camden, NJ 08103; Brunswick, GA 31520; Job site manufactured with local sand & water




 |   |   |