LATICRETE INTERNATIONAL, INC.
1 LATICRETE Park North
Bethany, CT 06524-3423 USA
Tel: (203) 393-0010
Toll-Free: (800) 243-4788
Fax: (203) 393-1684
E-mail: technicalservices@laticrete.com
Web site: http://www.laticrete.com
LATICRETE Blue 92 Anti-Fracture Membrane is a two-part system
consisting of a liquid rubber and reinforcing fabric. When cured,
it forms a highly flexible membrane. While the thin bed method
of tile installation provides many advantages, this method can be
affected by problems with shrinkage cracking in concrete and other
types of substrates. Cracks can telegraph through the tile and/or
grout joints. To reduce or eliminate cracks in tile work, a flexible
membrane should be applied to the cracked substrate prior to the
installations of ceramic tile, marble and stone.
- For interior or exterior use on floors and walls whenever
hairline cracking or "spiderwebbing" occurs in the substrate.
- For use over shrinkage and other non-structural cracks up to
1/8" (3 mm).
- Typical applications are over concrete slabs (suspended or
on grade) in malls, lobbies and residential applications under
ceramic tile, marble and stone.
- Use to cover joints in plywood underlayments, cement
backer boards, and concrete masonry on floors and walls.
- Also use over concrete floors and underlayments with radiant
heating systems.
- Reduces crack transmission in ceramic tile, thin brick, marble
and stone installed using thin-set method. Also ideal for use
under thin resin Terrazzo.
- Inhibits the growth of stain causing mold and mildew with
Microban® antimicrobial protection.
- Thin-adds no appreciable thickness to floor construction;
install tile with LATICRETE Polymer Fortified Thin-Set Mortar
directly to cured membrane.
- "Extra Heavy Service" rating per TCNA performance levels
(RE: ASTM C627 Robinson Floor Test).
- Easy to Apply-goes on quickly with paint brush or roller; no
mixing or special equipment required.
- Fast Cure-dries in a few hours to receive finished
surfacing.
- Easy Cleanup-cleans with water while fresh.
- Safe-no solvents or harsh fumes, non-flammable.
- Exterior glue plywood*
- Concrete
- Mortar beds, renders
- Cement backer board**
- Cement terrazzo***
- Ceramic Tile and Stone***
- Concrete masonry
* Interior applications only.
** Consult cement backer board manufacturer for specific installation recommendations and to
verify acceptability for exterior use.
*** If skim-coated with a LATICRETE® Latex Thin-Set Mortar
Full Unit consists of:
- 5 US gallon (19 l) pail liquid
- 1-roll reinforcing fabric: 38" (97 cm) wide, 95 ft (29 m) long
- 1-roll reinforcing fabric: 6" (15 cm) wide, 75 ft (23 m) long
Crack Suppression Kit (1/4 Unit) contains:
- 2 gallon (7.66 l) jug of liquid, 15" (37.5 cm) wide roll
Approximately 300 ft2 (28 m2) at 20 mil thickness per full unit.
Approximately 75 linear ft (23 linear meters) per crack suppression
kit.
Factory sealed containers of this product are guaranteed to be of first quality for two (2) years if stored at temperatures >32°F (0°C) and <110°F (43°C).
- LATICRETE® Blue 92 Anti-Fracture Membrane is not intended for use as a waterproofing membrane. When a waterproofing membrane is required, use a LATICRETE Waterproofing Membrane (see Section 10 FILING SYSTEMS).
- DO NOT use over expansion joints, structural cracks or areas with differential vertical movement.
- Adhesives/mastics, mortars and grouts for ceramic tile,
pavers, brick and stone are not replacements for waterproofing membranes.
- Apply to surfaces above 45°F (7°C). Maintain a constant temperature greater than 45°F (7°C) for 24 hours after
installation.
- Not intended as a wearing surface. Must be covered with tile, or other traffic bearing material.
- DO NOT bond to particle board, luan, Masonite® or hardwood surfaces.
- During cold weather, protect finished work from traffic until fully cured.
- For white and light-colored marbles use LATICRETE 220 Marble & Granite Mortar WHITE.
- For green resin backed agglomerates and moisture sensitive marbles, use LATAPOXY® 300 Adhesive. Refer to Data Sheet 633.0.
- Protect freshly installed membrane from water exposure.
This product has been GREENGUARD Indoor Air Quality Certified® by the GREENGUARD Environmental Institute under the GREENGUARD Standard for Low Emitting Products infinished form.
Total VOC Content pounds/gallon (grams/liter) of product in unused form is 0.02 lb/gal (2.39 g/l ).
ANSI A118.12
| Physical Properties |
Test Method |
LATICRETE® Blue 92 Anti-Fracture Membrane |
Proposed ANSI A118.12 |
| System Crack Resistance |
ANSI A118.12 5.4 |
Pass at 1/8 inch (3 mm) |
Pass at 1/8 inch (3 mm) |
| Elongation |
ASTM D751-89; 17.1 |
20-30% |
20-30% |
| Breaking Strength (Cut Strip Method) |
ASTM D751-89; 16.1 |
1700-1900 psi
(11.72â13.10 MPa) |
1700-1900 psi
(11.72â13.10 MPa) |
| Nominal Dry Thickness |
LIL 1013-92 |
0.020 inch
(0.51 mm) |
0.020 inch
(0.51 mm) |
| 28 day Quarry/Concrete Shear Strength |
ANSI A118.12 5.1.5 |
125-175 psi
(0.86-1.6 MPa) |
50 psi (0.34 MPa) |
| Point Load |
ANSI A118.12 5.2 |
3200-3700 lbf
(14-16 kN) |
1000 lbf (4.4 kN) |
Data from report 031219-P-182-176.
Specifications are subject to change without notification. Results shown are typical but reflect test
procedure used. Actual field performance will depend on the type of tile/stone used, installation
methods and site conditions.
Identify the type of crack in the substrate. DO NOT use LATICRETE Blue 92 Anti-Fracture Membrane over structural cracks or other areas with differential vertical movement.
Shrinkage Cracks: Occur during the curing process of the concrete. Typically the movement is horizontal (open and close).
Structural Cracks: Occur from improper design or installations of substructure for load conditions. Typical movement is vertical (up and down). LATICRETE Blue 92 Anti-Fracture Membrane is not intended to bridge joints which experience dynamic movement such as expansion joints and structural cracks. Expansion joints must be carried through the entire tile installation.
All surfaces should be between 45°F (7°C) and 90°F (32°C) and structurally sound, clean and free of all dirt, oil, grease, paint,
concrete sealers or curing compounds and cement latents. Rough or uneven concrete surfaces should be made smooth with LATICRETE Fortified Portland Cement Underlayment to provide a wood float or
better finish. Do not level with gypsum or asphalt based products. Dry, dusty concrete slabs or masonry should be cleaned, dampened and excess water swept off. Installation may be made on a damp surface. New concrete slabs shall be damp cured and a minimum of 14 days old before application (see membrane instructions WPAF.5 for additional information). All slabs must be plumb and true to within 1/4" (6 mm) in 10 ft (3 m). Skim coat existing ceramic tile and stone with a LATICRETE Latex Thin-Set Mortar.
- Installer must verify that deflection under all live, dead and impact loads of interior plywood floors does not exceed
industry standards of L/360 for ceramic tile and brick or L/480 for stone installations where L=span length.
- Minimum construction for interior plywood floors.
SUBFLOOR: 5/8" (15 mm) thick exterior glue plywood, either plain with all sheet edges blocked or tongue and groove, over bridged joints spaced 16" (400 mm) o.c. maximum; fasten
plywood 6" (150 mm) o.c. along sheet ends and 8" (200 mm)
o.c. along intermediate supports with 8d ring-shank, coated or hot dip galvanized nails (or screws); allow 1/8" (3 mm)
between sheet ends and 1/4" (6 mm) between sheets edges; all sheet ends must be supported by a framing member; glue sheets to joints with construction adhesive;
UNDERLAYMENT: 5/8" (15 mm) thick exterior glue plywood fastened 6" (150 mm) o.c. along sheet ends and 8" (200 mm)
o.c. in the panel field (both directions) with 8d ring-shank, coated or hot dip galvanized nails (or screws); allow
1/8" (3 mm) to 1/4" (6 mm) between sheets and
1/4" ( 6 mm) between sheet edges and any abutting surfaces; offset underlayment joints from joints in subfloor and stagger joints between sheet ends; glue underlayment to subfloor with construction adhesive. Refer to Technical Data Sheet 152 Bonding Ceramic Tile, Stone or Brick Over Wood Floors.
Pre-treat Cracks: Apply a liberal coat of liquid 8" (20 cm) wide over crack. Embed 6" (15 cm) wide reinforcing fabric into first coat of liquid. Liberally apply 2nd coat of liquid to seal fabric.
Main Membrane Application: Once surface of crack pre-treatment
has dried to the touch, use a wide brush/paint roller to cover substrate with a liberal coat of LATICRETE Blue 92 Anti-Fracture Membrane liquid. Cover an area slightly wider than the reinforcing
fabric width (>38" [97 cm]). Embed fabric while liquid is still wet. Press firmly with brush or roller to allow complete "bleed through" of liquid. Apply additional liberal coat of LATICRETE® Blue 92
Anti-Fracture Membrane liquid to cover/saturate fabric. Lap fabric 2" (5 cm) at seams. When final coat of liquid has dried to the touch (2-3 hours), install ceramic tile, brick or stone with a LATICRETE Polymer Fortified Thin-Set Mortar or a LATAPOXY® 300 Adhesive. Treat closest joint to cold or saw cut joint LATICRETE Latasil™.
LATICRETE and LATAPOXY materials are available worldwide.For distributor information, call:
Toll Free: 1.800.243.4788
Telephone: +1.203.393.0010
For on-line distributor information, visit LATICRETE at
www.laticrete.com.
Contact a LATICRETE/LATAPOXY Distributor in your area.
See 10. FILING SYSTEM
| DS 230.13: |
LATICRETE Product Warranty |
A component of:
| DS 230.12: |
LATICRETE 10 Year Systems Warranty |
LATICRETE and LATAPOXY grouts require routine cleaning with a neutral pH soap and water. All other LATICRETE and LATAPOXY materials require no maintenance but installation performance and durability may depend on properly maintaining products supplied by other manufacturers.
Information is available by calling the LATICRETE Technical Service Hotline: (hours 8:00 AM to 5:30 PM EST):
Toll Free: 1.800.243.4788, ext. 235
Telephone: +1.203.393.0010, ext. 235
Fax: +1.203.393.1948
To acquire technical and safety literature, please visit our website
at www.laticrete.com.
Additional product information is available on our website at www.laticrete.com. The following is a list of related documents:
| DS 230.13: |
LATICRETE Product Warranty |
| DS 230.12: |
LATICRETE 10 Year Systems Warranty |
| DS 236.0: |
LATICRETE 9235 Waterproofing Membrane |
| DS WPAF.5: |
Installation of LATICRETE Membranes |
| DS 633.0: |
LATAPOXY 300 Adhesive |
| DS 297.0: |
LATICRETE 220 Marble & Granite Mortar |
| DS 6200.1: |
LATICRETE Latasil |
| TDS 152: |
Bonding Ceramic Tile, Stone or Brick Over Wood Floors |
|