Knauf Pipe and Tank Insulation with ECOSE® Technology is a semi-rigid fiber glass board in roll form faced with a factory applied FSK or ASJ vapor retarder or a glass mat facing. The glass fibers are adhered perpendicular to the jacketing, for flexibility and easy installation.
ECOSE Technology is a revolutionary new binder based on rapidly renewable bio-based materials rather than non-renewable petroleum-based chemicals such as phenol, formaldehyde or acrylics. ECOSE Technology reduces Knauf binder embodied energy and contains no phenol, formaldehyde, acrylics or artificial colors found in traditional fiber glass insulation.
Knauf Pipe and Tank Insulation with ECOSE Technology is typically used on tanks, vessels and large-diameter pipes. It can be used for any curved or irregular surfaces that require finished characteristics of rigid fiber glass insulation.
- Temperature ratings to 850°F (454°C)
- Flexible
- Easy to handle and fabricate
- No need to stock multiple sizes
- Various thicknesses available to meet all your pipe and tank insulation needs
- Tough and durable
- Resists damage in shipment, during and after installation
- Does not promote the growth of fungi or bacteria
- Will not rot
- Will not sustain vermin
- Does not accelerate corrosion on steel, copper or aluminum
- The corrosion rate in mils/yr will not exceed that of the 1 ppm chloride solution
Carbon negative: meaning Knauf thermal insulation products recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place.
Fiber glass insulation with ECOSE Technology contains three primary ingredients:
- Sand, one of the world's most abundant and renewable resources
- Post-consumer recycled bottle glass
- ECOSE Technology which reduces binder embodied energy by up to 70%
- ASTM C 1136
- – Type I, II, III, IV (ASJ)
- – Type II, IV (FSK)
- HH-B-100B (jackets)
- – Type I and II (ASJ)
- – Type II (FSK)
- HH-I-558C; Form A, Class 3
- Operating temperature to 850°F (454°C)
- Not less than 150 PSF (7.18 kPa) at 10% deformation for 2" (51 mm) thickness
- Not less than 275 PSF (13.2 kPa) at 10% deformation for 3" (76 mm)
- Both FSK and ASJ vapor retarders have a maximum vapor transmission rate of .02 perms
- FSK Facing: 25
- ASJ facing: 50
- Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, NFPA 255 and UL723
| Mean Temperature |
Mean Temperature (SI) |
k |
k (SI) |
| 100°F |
38°C |
.26 |
.037 |
| 200°F |
93°C |
.35 |
.050 |
| 300°F |
149°C |
.45 |
.065 |
| 400°F |
204°C |
.57 |
.082 |
| 500°F |
260°C |
.75 |
.108 |
Knauf Insulation products with ECOSE Technology are certified for indoor air quality as a low emitting product by The GREENGUARD Environmental Institute to both the GREENGUARD Certification ProgramSM and the more stringent GREENGUARD for Children and SchoolsSM standard. http://www.greenguard.org/
Use of this product may help building projects meet green building standards as set by the Leadership in Energy and Environmental Design (LEED) Green Building Rating System.
- MR Credit 4.1 – 4.2 Recycled Content
- MR Credit 5.1 – 5.2 Regional Materials
- ID Credit 1 GREENGUARD For Children & Schools
| Thickness |
Width* |
Length |
| 1" (25 mm) |
36" (914 mm) |
48' (14.63 m) |
| 1/2" (38 mm) |
36" (914 mm) |
32' (9.75 m) |
| 2" (51 mm) |
36" (914 mm) |
24' (7.32 m) |
| 2 1/2" (64 mm) |
36" (914 mm) |
19' (5.79 m) |
| 3" (76 mm) |
36" (914 mm) |
16' (4.88 m) |
| 3 1/2" (89 mm) |
36" (914 mm) |
14' (4.67 m) |
| 4" (102 mm) |
36" (914 mm) |
12' (3.66 m) |
*Cut-to-length sizes also available
Nominal Iron
Pipe Size |
Iron Pipe
Outside Diameter |
|
Thickness |
|
|
| |
1"
(25 mm) |
1 1/2"
(38 mm) |
2"
(51 mm) |
3"
(76 mm) |
10"
(254 mm) |
10 3/4"
(273 mm) |
40 1/8"
(1019 mm) |
43 1/4"
(1099 mm) |
46 3/8"
(1178 mm) |
52 5/8"
(1337 mm) |
12"
(305 mm) |
12 3/4"
(324 mm) |
46 3/8"
(1178 mm) |
49 1/2"
(1257 mm) |
52 3/4"
(1340 mm) |
59"
(1499 mm) |
14"
(356 mm) |
14"
(356 mm) |
50 3/8"
(1280 mm) |
53 1/2"
(1359 mm) |
56 5/8"
(1438 mm) |
62 1/8"
(1597 mm) |
16"
(406 mm) |
16"
(406 mm) |
56 5/8"
(1438 mm) |
59 3/4"
(1518 mm) |
62 1/8"
(1597 mm) |
69 1/8"
(1756 mm) |
18"
(457 mm) |
18"
(457 mm) |
62 1/8"
(1597 mm) |
66"
(1676 mm) |
69 1/8"
(1756 mm) |
75 1/2"
(1918 mm) |
20"
(508 mm) |
20"
(508 mm) |
69 1/8"
(1756 mm) |
72 3/8"
(1838 mm) |
75 1/2"
(1918 mm) |
81 3/4"
(2076 mm) |
22"
(559 mm) |
22"
(559 mm) |
75 1/2"
(1918 mm) |
78 5/8"
(1997 mm) |
81 3/4"
(2076 mm) |
88"
(2235 mm) |
24"
(610 mm) |
24"
(610 mm) |
81 3/4"
(2076 mm) |
84 7/8"
(2156 mm) |
88"
(2235 mm) |
94 3/8"
(2397 mm) |
26"
(660 mm) |
26"
(660 mm) |
88"
(2235 mm) |
91 1/3"
(2315 mm) |
94 3/8"
(2397 mm) |
100 5/8"
(2556 mm) |
28"
(711 mm) |
28"
(711 mm) |
94 3/8"
(2397 mm) |
97 1/2"
(2477 mm) |
100 5/8"
(2556 mm) |
106 7/8"
(2715 mm) |
30"
(762 mm) |
30"
(762 mm) |
100 5/8"
(2556 mm) |
103 3/4"
(2635 mm) |
106 7/8"
(2715 mm) |
113 1/8"
(2873 mm) |
32"
(813 mm) |
32"
(813 mm) |
106 7/8"
(2715 mm) |
110"
(2794 mm) |
113 1/8"
(2873 mm) |
119 1/2"
(3035 mm) |
34"
(864 mm) |
34"
(864 mm) |
113 1/8"
(2873 mm) |
116 1/4"
(2953 mm) |
119 1/2"
(3035 mm) |
125 3/4"
(3194 mm) |
36"
(914 mm) |
36"
(914 mm) |
119 1/2"
(3035 mm) |
122 5/8"
(3115 mm) |
125 3/4"
(3194 mm) |
132"
(3353 mm) |
38"
(965 mm) |
38"
(965 mm) |
125 3/4"
(3194 mm) |
128 7/8"
(3273 mm) |
132"
(3353 mm) |
138 1/4"
(3512 mm) |
40"
(1016 mm) |
40"
(1016 mm) |
132"
(3353 mm) |
135 1/8"
(3432 mm) |
138 1/4"
(3512 mm) |
144 5/8"
(3673 mm) |
42"
(1067 mm) |
42"
(1067 mm) |
138 1/4"
(3512 mm) |
141 1/2"
(3594 mm) |
144 5/8"
(3673 mm) |
150 7/8"
(3832 mm) |
*Additional 2" (51 mm) to 4" (102 mm) should be added for lap.