Metal Roofing Englert Series 2400
Englert, Inc.
1200 Amboy Avenue
P.O. Box 149
Perth Amboy, NJ 08861
Tel: (732) 826-8614
Fax: (732) 826-8865
Email: englert.inc@prodigy.net
Web site: http://www.englertinc.net
PRODUCT PRESENTATION
Englert Series 2400 2" high seam is a variable width (12" to
24") roof panel system rollformed with optional stiffening ribs, with
clip offset feature. The panels are secured by fixed or floating clips,
allowing for unrestricted thermal movement and seamed by electric seamers.
The 2" high seam panel features an anticapillary hem. All fasteners
are concealed. (On 2400 2" high panels going over purlins, anchor
clips at every purlin with 2 fasteners per clip.)
As an integrated roofing system, 2" high seam, minimum slope is
1/2"/12" for panels up to 75' long and 1"/12" for
panels over 75'-100' long with sealant. Check with the manufacturer for
specific applications. 2400, 2" high 18" panel system meets the
structural requirements of UL for Class 90 wind uplift resistance at 4'
o.c. over 16 gauge purlins. Check with the manufacturer for specific
details on UL-90 ratings.
SPECIFICATIONS
A. Panel system should be the Englert Series 2400, 2" seam x 18"
wide panel Structural Standing Seam System, (with pencil ribs and 2
mechanically seamed styles available). Mechanical seaming available in 90°
and 180°. The panels shall have baked on finish as specified in
Section 2.05 hereunder, in Manufacturers standard colors.
Manufacturer shall offer at least a minimum of 23 standard colors to
choose from.
B. Substrate
- 24 gauge baked on finish over Galvalume ASTM A-792-83, AZ55, 40 KSI
yield point, 52 KSI tensile strength.
- *22 gauge baked on finish over Galvalume per ASTM A-792-83, AZ55, 40
KSI yield point, 52 KSI tensile strength.
- *.032" or .040" aluminum alloy 3105-H14 approved equal.
NOTE TO SPECIFIER: *22 gauge steel, and .032" and
.040" aluminum are available subject to minimum order requirements.
Call Englert for details.
C. Performance
1. Panel shall meet the requirements of Underwriters Laboratories,
Inc. for Class 90 wind uplift resistance.
2. ASTM E-283-84 air infiltration: Maximum of 0.003 CFM./Ft²
at 10 psf pressure differential on 180° seamed profile and 0.006
CFM./Ft² at 20 psf pressure differential.
3. ASTM E-331-84 water penetration: No evidence of uncontrolled leakage
on 180° seamed panel at 20 psf pressure differential.
4. Panel shall display a flame spread classification of a Class 1 when
tested in accordance with ASTM E-84-87.
NOTE TO SPECIFIER: Series 2400 panels 2" x 18"
wide in 24 gauge Galvalume meet the Underwriters Laboratories, Inc. 580
classification for 90 lb. per square foot up lift test when installed over
purlins at 4'0" o.c. with special clips.
Englert, Inc.
1200 Amboy Avenue
P.O. Box 149
Perth Amboy, NJ 08861
Tel: (732) 826-8614
Fax: (732) 826-8865
Email: englert.inc@prodigy.net
Web site: http://www.englertinc.net
Englert, Inc.
Colorado
Phone: (303) 288-8070
Connecticut
Phone: (203) 265-6704
Florida
Phone: (813) 248-2296
Massachusetts
Phone: (508) 774-0006
New Jersey
Phone: (732) 826-8610
Pennsylvania
Phone: (412) 461-1355
Tennessee
Phone: (423) 970-0090
Virginia
Phone: (703) 922-9666
(757) 363-0622