PANEL & SYSTEM DESCRIPTION

PRODUCT NAME:
Envelope 2000®
Engineered Architectural Wall System

OVERVIEW:
Envelope 2000® is a fabricated wall system utilizing a composite panel made by laminating a prefinished aluminum skin to a substrate of thermoset phenolic resin. A second aluminum skin is added as a backer and provides thermal stability and panel balance. Panels are furnished with a strippable film on the painted surfaces to protect the finish during shipment and installation. Envelope 2000® is fabricated and then attached to the substrate with a series of aluminum extrusions. The three basic attachment methods for Envelope 2000® are the Reveal System (RV) utilizing one piece extruded aluminum moldings, the Rout & Return System (RR) with formed ‘pans’ and attachment extrusions and the RainScreen System (RS) utilizing formed ‘pans’, attachment extrusions and featuring ‘dry’ joints.

BASIC USES & APPLICATIONS:
As a high end fabricated system, Envelope 2000® is designed for use as an exterior cladding on walls, canopies, fascia, and accent bands. Envelope 2000® is typically used on medium to high rise buildings, such as office towers, retail complexes, educational buildings, medical facilities, etc...

GENERAL LIMITATIONS:
Envelope 2000® is intended for use as an exterior cladding. It is not eligible for use as a structural element of a wall assembly. Envelope 2000® should not be used in applications where the slope exceeds 25° from vertical.

SYSTEM FINISHES:
Envelope 2000® comes standard with a smooth aluminum skin. Standard and metallic colors are furnished with a durable Kynar 500® coating. Anodized finishes are available as a standard finish. Custom colors are also available to match customer’s standard. Moldings (Reveal System) are coated using a Kynar 500® paint system and can be painted to match any standard or custom color.

INSTALLATION OVERVIEW

REVEAL SYSTEM (RV):
Utilizing one piece extruded aluminum moldings, this is a barrier system that features a progressive installation. The moldings are mechanically fastened to the substrate. The panels are then inserted into the moldings, along with sealant and attached to the substrate using construction adhesive at intermediate locations. Reveal (1/2” typical, 3” also available) and batten profile moldings are standard.

ROUT & RETURN SYSTEM (RR):

Barrier system in which panels are fabricated and formed into ‘pans’ and then ‘hung’ on the substrate using aluminum extrusions. All fasteners are concealed and panel joints (1/2” reveal typical) are finished with an approved sealant.

RAINSCREEN SYSTEM (RS):

Based on the ‘rainscreen principle’, this system allows incidental water to enter the cladding cavity, but then be drained through the system via weepholes. Also utilizing formed panels, this system is attached using aluminum extrusions. Panel joints are finished using color matched or complementary accent strips that ‘float’ in the extrusions providing a reveal from 1/2” to 12”.

TABLE 1. COMPOSITION & MATERIALS¹:

Component
Standard (in)
Metric (mm)
  • Prefinished Smooth Aluminum Face
  • Thermoset Phenolic Resin Core²
  • Primed Smooth Aluminum Backer
.024”(min)
.105”
.010”
.609mm
2.67mm
.254mm
¹ Technical Properties are based upon the Typical Composition. Selecting optional components may
alter these properties.
² 4mm is the most common thickness for Envelope 2000®. 3mm and 6mm (nominal) are also available.

FEATURES & BENEFITS:
As a complete exterior cladding system, Envelope 2000® offers a number of benefits to the building owner, architect, and installer including:

  • High-Tech Appearance
    Smooth aluminum skins and clean lines make Envelope 2000® an excellent choice for high profile projects where a progressive aesthetic detail is desired.
  • Versatile Installation
    With three different attachment options, virtually any look can be created using different shadow line sizes and treatments at the panel joints.
  • Curveable
    Along with various shadow lines, Envelope 2000® can also add interest to your project with long sweeping curves or tight, crisp column covers.
  • Thermal Stability
    Unlike other cladding solutions, Envelope 2000® systems remain rigid and stable even during seasonal heating and cooling thermal cycles.
  • Durable
    An innovative thermoset phenolic resin core provides these panels with superior impact and dent resistance.
  • Low Maintenance
    Most foreign matter can be cleaned from surface with mild detergents; can be incorporated into yearly building washing schedule.
TABLE 2. PANEL WEIGHT & THICKNESS:
Component
Standard (in)
Metric (mm)
Panel Weight¹
Nominal Thickness
1.33 lbs/ft²
1/8”
6.47 kg/m²
4mm

TABLE 3. PANEL PERFORMANCE:
Property Test Value Unit
R-Value --- 0.05 °F ft²/BTU
Flame Spread ASTM E84 Class A ---
Peel Strength ASTM D1781 34.5 lb-in/lb
Stiffness (EI)¹ ASTM E72 1.27 E+4 lb-in²/ft width
Allowable Bending Moment¹ ASTM E72 1.82E+1 lb-ft/ft width
Tensile Yield¹ ASTM E72 7.34E+3 lb/ft width
Ultimate Tensile¹ ASTM E72 1.04E+4 lb/ft width
Coefficient Of Thermal ASTM D1237 1.11E-5 in/in/°F
Expansion      
Ignition Temperature ASTM D1929 900 ° F
¹ Weight and testing based upon panels using an .024” smooth face skin and an .010” smooth back skin.

MATERIAL TOLERANCES: SIZES AVAILABLE:
Thickness: ±1/32” (±0.79mm) 48” x 96” (1219mm x 2438mm)
Length Dim: +0, -1/16” (+0, -1.59mm) 48” x 120” (1219mm x 3048mm)
Width Dim: +0, -1/16” (+0, -1.59mm) 48” x 144” (1219mm x 3658mm)
Squareness: 1/64” (0.4mm) per 60” x 96” (1524mm x 2438mm)
  lineal foot 60” x 120” (1524mm x 3048mm)
  60” x 144” (1524mm x 3658mm)
   
Envelope 2000® is supplied with clean,
machine trimmed edges.
Cut-to-size panels are also available in
virtually any size up to 60” x 144”.

PANEL FINISH SYSTEMS:
Standard Textured: Coil Coated
  Kynar 500®
Custom Textured: Spray Applied
  Kynar 500®
   
STANDARD WARRANTY:
 
Panel Warranty: 5 Years
Kynar 500® Finish: 20 Years
No change greater
than 8 for chalk,
5 E units for fade
Anodized Finish: 20 Years (prorated)
   
CODE CERTIFICATION¹:
 
ICBO (International Conference Of Building Officials) - #PFC-5792
 
BOCA (Building Officials Code Administrators) - #21 • 08
 
 
SBCCI PST & ESI (Southern Building Code Congress International, Public Safety Testing & Evaluation Services Inc.) - #2046 
¹ Envelope 2000® RR attachment system.


 |   |   |