Advance Lifts, Inc.
701 S. Kirk Road
St. Charles, IL 60174-3428
Toll Free: (800) 843-3625
Tel: (630) 584-9881
Fax: (630) 584-9405
E-mail: sales@advancelifts.com
Web site: http://www.advancelifts.com
The convenience of a dock lift without the expense of a concrete pit.
That's what you get with surface mounted dock lifts.
Series 6000 top of ground dock lifts are installed on
top of a concrete pad. These models cant be installed in pits because
their low lowered height does not permit the addition of the 8" bevel toe
guards required by OSHA for pit mounted lifts. Platform sizes range from
6 x 8 to 6 x 12. Capacities range from 5,000 to 12,000 lbs. Models
6100 and 6150 have hinged approach ramps with built in wheel chocks to
prevent loads from rolling off the raised platform while models 6200 and
6300 have fixed approach ramps. Model 6150 has its power unit built right
onto the platform while the other models have remote power units.
-
Conformance with OSHA, BOCA, ANSI, and the National Electrical Code.
-
Positive mechanical stops within the hydraulic cylinders.
-
24 volt, 4 amp fused control circuit.
-
Starter, 3 pole adjustable overloads and 24 volt transformer prewired in
a NEMA 12 enclosure.
-
Power unit and controls completely prewired and ready for plug-in.
-
Control cord prewired to controller and push button.
-
Power cord with twist lock plug.
-
Removable safety leg(s).
-
Anodized aluminum hydraulic valve manifold.
-
A minimum of 2 in-line hydraulic filters.
-
20 ft. of 1/2 in. SAE-100R2 hydraulic hose(s) with hose cover for 6100,
6200, 6300 models. Not requires for other models.
-
Lifetime lubricated bearings.
-
Chrome plated axles, shafts and rods.
-
Baked on enamel finish.
- Reinforce concrete to suit local soil conditions.
- All concrete work is the responsibility of the owner or his agent.
- Installer to run 1/2" diameter hose(s) from the power unit to the
lift base (6100, 6200, 6300 models only).
- Concrete pad must be flat and level.
-
One (1) Advance Model Number _______.
-
One (1) length 16/4 SJO control card for the push button.
-
20 ft. 1/2" SAE 100R2 hydraulic pressure hose from the power unit location
to the lift base-1/2" male #8JIC threads on both ends. 6100-1 hose. 6200
& 6300-2 hoses.
-
20 ft. of metal hose cover (6100, 6200, & 6300 Series only.)
-
One (1) electric disconnect switch for 2 or SHP motor.
-
One (1) plug receptacle.
-
Dextron III motor oil for the power unit reservoir. 6100-5 gallons. 6200
& 6300-10 gallons. Included with 1000 Series & 6150.
-
Concrete anchor bolts and material for shimming and/or grouting.
*Seller furnishes items 1 through 4 only unless otherwise agreed to in
writing.
|