Multi-Purpose Panel
ATAS International, Inc.
Corporate Headquarters:
Allentown, PA
Western Facility:
Mesa, AZ
Southern Facility:
Maryville, TN
Toll-Free: (800) 468-1441
Tel: (610) 395-8445
Fax: (610) 395-9342
E-mail: info@atas.com
Web site: http://www.atas.com
Product Presentation
Multi-Purpose panels with the Wind-Lok application have a smooth, sleek
appearance with a concealed clipless fastening system. These panels are
typically used for siding, fascias, mansards and equipment screens.
Sizes and Profiles:
Four 8" wide panels, seven 12" wide panels and six 16" wide panels are
available. The semi-standing seam (MPN code), the batten style (MPW code)
and the plank or barn board (MPH code) give completely different appearances.
A slight V in the MPH series gives another variation in style (MPV code).
Panel lengths are cut to customer specifications.
Composition and Materials:
Panels are roll-formed from .032 or .040 Aluminum or 24 gauge Metallic Coated
Steel. Twenty-two gauge steel is available in select colors only.
Color and Finish:
A choice of 30 colors is available in a Kynar 500® or Hylar 5000®
based finish. (Request color chart or chips.) An anodized finish is available
in clear or dark bronze.
Texture may be smooth or stucco embossed.
Specifications
Note to specifiers: Multi-Purpose Panel System serves
the architectural needs of wall and mansard systems. For detailed product
specifications in a 3-part standard format visit our web site at www.atas.com
Technical Data
Paint Finish
a Kynar 500® or Hylar 5000® based paint system
Tested by PPG Industries for:
Dry Film Thickness (Nominal): ASTM D-1400-94, D-1005-95, ASTM D 4138 or ASTM D 5796, Eddy
current device or micrometer
Consists of 0.2 ± 0.05 mil primer on both sides with 0.8 ±
0.1 mil 70% PVDF topcoat.
Gloss: ASTM D523-89 at 60°
Standard shall have a gloss of 30 ±.
Pencil Hardness: ASTM D-3363-92a Eagle Turquoise Drafting Lead
HB-H
Formability T-Bend: ASTM D- 4145-96
No cracking or tape removal of film at 1-T bend (aluminum); 2-T bend
(coated steel).
Formability Mandrel: ASTM D-522-93a 180° Bend around 1/8
mandrel
No cracking
Adhesion: ASTM D-3359-95a Rev. impacted 1/16 crosshatch
No adhesion loss
Reverse Impact: ASTM D-2794-93 Impact in in./lb. = 1,500 x metal
thickness in inches (aluminum) or 3000 x metal thickness in inches (coated
steel)
No cracking or adhesion loss
Water Immersion Resistance: ASTM D 870
Abrasion Resistance, Falling Sand Test: ASTM D-968-93 Liters
to expose 5/32 of substrate
50 to 80 liters
Abrasion Resistance, Transit: proprietary procedure, Panels Tested
Face-to-Back
No disfigurement
Mortar Resistance: AAMA 2605, Test #7.7.2 - 24 hour Pat Test
No effect
Detergent Resistance: ASTM D-2248-93 3% DET., 100° F, 72
hrs. immersion
No effect
Graffiti Resistance: Cleanability of Defaced Panels, spray paint,
various marking pens
No disfigurement after cleaning.
Acid Pollutants Resistance: ASTM D-1308-87. (1993), 10% muriatic
acid, 15 min.
No effect
20% sulfuric acid, 18 hrs.
No effect
AAMA 2605, Test #7.7.3.1 70% nitric acid vapors, 30 mins.
<5 units color change.
Acid Rain Resistance Test: Kesternich Sulfur dioxide cyclic test
10 cycles minimum; no objectionable color change
Alkali Resistance: ASTM D-1308-93, 25% sodium hydroxide, 1 hr.
No effect
Salt Fog: ASTM B 117-95 - 5% Salt Fog at 95° F
Passes 3,000 hours (aluminum) with less than 1/16 maximum average
creepage from scribe; passes 1,000 hours (coated steel) with less than
1/8 maximum average creepage from scribe.
Cyclic Salt Spray: ASTM D 5894 and ASTM D 5487
Humidity Test: ASTM D-2247-94/D-714-94 100% Relative Humidity
at 95° F
Passes 3,000 hours (aluminum) with no blisters; Passes 1,500
hours (coated steel) with no blisters.
Color Retention, Weatherometer Test: ASTM D-822-96, G23-93, G26-90,
G53-93
Passes 5,000 hours, no objectionable chalking, color change or adhesion
loss.
Color Retention, Florida Exposure: ASTM D-2244-93, Florida exposure:
10 years at 45° S.
Maximum 5 units change.
Chalking Resistance: ASTM D-4214-89, Test Method D 659, Florida
exposure: 10 years at 45° S.
Maximum rating of 8.
Cleveland Condensing Cabinet: ASTM D 4585
Cure Test, MEK Resistance: ASTM D 5402
Flame Spread Rating: ASTM E 84
Panel testing/ratings:
Uplift/Load Data
UL790
UL580
UL90
Fire Rating: Class A, B & C
ASTM E-283
ASTM E-331
AAMA 501.1
ASTM B 209 Aluminum
ASTM A 653 Steel
ASTM B 209
ASTM A 755
FSR Flame Spread Rating
Field Tested and Approved
Warranty
The Kynar 500® or Hylar 5000® based paint finish carries a thirty
(30) year limited warranty against chipping, cracking, peeling, chalking
and fading.
Availability and Cost
Multi-Purpose panels are readily available through ATAS product distributors.
Cost:
Contact ATAS product distributors for cost.
Installation
Installation is achieved by interlocking the panel into the preceding
panel and fastening with mechanical fasteners. The rib of the adjoining
panel will conceal the fasteners. Installation manuals or hands-on training
through seminars are available. Contact ATAS technical service advisors
for information.
Maintenance
Multi-Purpose panels are virtually maintenance free. The high quality
finish will not fade, chalk, crack or peel, and since the substrate is
metal, the panel will not warp, rot or break. Surface residue may be easily
removed by conventional cleaning methods. Minor scratches may be touched
up with a matching paint, available from the manufacturer.
Technical Services
Complete technical information and literature is available from ATAS
International, Inc. ATAS will assist with design ideas and estimates and
offers shop-drawing services.
Kynar 500® is a registered trademark of Elf Atochem North America,
Inc.
Hylar 5000® is a registered trademark of Ausimont USA, Inc.
|