Monarch Panels
Batten Roof Systems
ATAS International, Inc.
Corporate Headquarters:
Allentown, PA
Western Facility:
Mesa, AZ
Southern Facility:
Maryville, TN
Toll-Free: (800) 468-1441
Tel: (610) 395-8445
Fax: (610) 395-9342
E-mail: info@atas.com
Web site: http://www.atas.com
Product Presentation
Sizes and Profiles:
MONARCH panels are available in two profiles: the Batten, and the
Standing or Dutch Seam (see Dutch Seam Standing Seam Panel product
profile). The batten and lock are an integral part of the panel. The
Batten style is either 12 wide (MRB120) or 16 wide (MRB160). Panel lengths
are cut to customer specifications, with a minimum of 4 and a maximum
to transportation limitations. Specify with or without stiffening ribs.
Composition and Materials:
MRB Batten Seam panels are available in .032, .040 and .050 Aluminum
22 and 24 gauge metallic coated Steel, and 24 gauge 55% Al-Zn Alloy Coated Steel with Acrylic. Color and Finish:
A choice of 27 colors is available in a Kynar 500® or Hylar 5000®
based finish. (Request color chart or chips.) An anodized finish is available
in clear or dark bronze.
Texture may be smooth or stucco embossed.
Specifications
Note to specifiers: Monarch roof panels serve the structural
and architectural needs of roof and mansard systems. For detailed product
specifications in a 3-part standard format visit our web site at www.atas.com
Technical Data
Paint Finish
a Kynar 500® or Hylar 5000® based paint system
Tested by PPG Industries for:
Dry Film Thickness (Nominal): ASTM D-1400-94, D-1005-95, ASTM D 4138 or ASTM D 5796, Eddy
current device or micrometer
Consists of 0.2 ± 0.05 mil primer on both sides with 0.8 ±
0.1 mil 70% PVDF topcoat.
Gloss: ASTM D523-89 at 60°
Standard shall have a gloss of 30 ±.
Pencil Hardness: ASTM D-3363-92a Eagle Turquoise Drafting Lead
HB-H
Formability T-Bend: ASTM D- 4145-96
No cracking or tape removal of film at 1-T bend (aluminum); 2-T bend
(coated steel).
Formability Mandrel: ASTM D-522-93a 180° Bend around 1/8
mandrel
No cracking
Adhesion: ASTM D-3359-95a Rev. impacted 1/16 crosshatch
No adhesion loss
Reverse Impact: ASTM D-2794-93 Impact in in./lb. = 1,500 x metal
thickness in inches (aluminum) or 3000 x metal thickness in inches (coated
steel)
No cracking or adhesion loss
Abrasion Resistance, Falling Sand Test: ASTM D-968-93 Liters
to expose 5/32 of substrate
50 to 80 liters
Abrasion Resistance, Transit: proprietary procedure, Panels Tested
Face-to-Back
No disfigurement
Mortar Resistance: AAMA 2605, Test #7.7.2 - 24 hour Pat Test
No effect
Detergent Resistance: ASTM D-2248-93 3% DET., 100° F, 72
hrs. immersion
No effect
Graffiti Resistance: Cleanability of Defaced Panels, spray paint,
various marking pens
No disfigurement after cleaning.
Acid Pollutants Resistance: ASTM D-1308-87. (1993), 10% muriatic
acid, 15 min.
No effect
20% sulfuric acid, 18 hrs.
No effect
AAMA 2605, Test #7.7.3.1 70% nitric acid vapors, 30 mins.
<5 units color change.
Acid Rain Resistance Test: Kesternich Sulfur dioxide cyclic test
10 cycles minimum; no objectionable color change
Alkali Resistance: ASTM D-1308-93, 25% sodium hydroxide, 1 hr.
No effect
Salt Fog: ASTM B 117-95 - 5% Salt Fog at 95° F
Passes 3,000 hours (aluminum) with less than 1/16 maximum average
creepage from scribe; passes 1,000 hours (coated steel) with less than
1/8 maximum average creepage from scribe.
Humidity Test: ASTM D-2247-94/D-714-94 100% Relative Humidity
at 95° F
Passes 3,000 hours (aluminum) with no blisters; Passes 1,500
hours (coated steel) with no blisters.
Color Retention, Weatherometer Test: ASTM D-822-96, G23-93, G26-90,
G53-93
Passes 5,000 hours, no objectionable chalking, color change or adhesion
loss.
Color Retention, Florida Exposure: ASTM D-2244-93, Florida exposure:
10 years at 45° S.
Maximum 5 units change.
Chalking Resistance: ASTM D-4214-89, Test Method D 659, Florida
exposure: 10 years at 45° S.
Maximum rating of 8.
Panel testing/ratings:
Uplift/Load data
UL790, UL580, Class 90
Class A & B Fire Rating
ASTM E-283, ASTM E-33
ASTM E-333
ASTM B 209 Aluminum
ASTM A 653/A775 Steel
FSR Flame Spread Rating
Field Tested and Approved
Load Tables available upon request.
Warranty
The Kynar 500® or Hylar 5000® based paint finish carries a thirty
(30) year limited warranty against chipping, cracking, peeling, chalking
and fading.
Availability and Cost
MONARCH panels are readily available through ATAS product distributors.
A complete line of accessories in matching or coordinating colors is available
to complete a project. Valleys, Ridge Caps, Gable and Eave trims are formed
to customer specifications. Ridge Caps, Soffit or other Trim Designs can
be lanced for ventilation. Coil stock or flat sheet can be provided for
field fabrication of custom flashings.
Cost:
Contact ATAS product distributors for cost.
Installation
With the lock and seam being an integral part of the panel, there are
no caps or strips to install. Field seaming of the panel is not required.
The panel is snapped onto the previously installed panel, a clip is hooked
over the leg of the panel, and this is concealed by the batten of the
consecutive panel. A 4 in 12 slope is recommended. Minimum slope is 2:12. ATAS also manufactures
a complete lightweight framing system for converting flat roofs to the
correct slope.
Maintenance
MONARCH panels are virtually maintenance free. The high quality finish
will not fade, chalk, crack or peel, and since the substrate is metal,
the panel will not warp, rot or break. Surface residue may be easily removed
by conventional cleaning methods. Minor scratches may be touched up with
a matching paint, available from the manufacturer.
Technical Services
Complete technical information and literature is available from ATAS
International, Inc. ATAS will assist with design ideas and estimates and
offers shop-drawing services.
Kynar 500® is a registered trademark of Elf Atochem North America,
Inc.
Hylar 5000® is a registered trademark of Ausimont USA, Inc.
|